SINV-Sh Non-electric initiating System
 |
SINV-Sh system is sensitive to initiating impulse from SINV-P detonating cap, detonating cords and electric detonator. SINV-Sh detonating cap initiates 6ZhV ammonite cartridges and boosters. SINV-Sh shock tube is 2, 4, 7, 10 or 16 m, as per customer demand. Devices packed by 5 to 20 pieces are laid in plastic bags and shipped in boxes. One box fits 240 devices. UN number: 0360. Classification code: 1.1 B.
|
SINV-SH specification
|
Parameters |
SINV-Sh Device |
| Shock tube external diameter, mm |
3.2 |
| Weight of explosives in shock tube, mg/m |
20 |
|
Transmission rate of initiating signal through shock wave tube, m/s |
2000 |
|
Minimum
tensile strength with operation ability retained, N
Connection of shock tube with detonating cap |
200.0 80.0 |
| Water resistance, kgf/cm2 |
6 hours at 1.0 kgf/cm2 |
|
Operating temperature, °С |
40°С below zero to 50°С above zero |
| Number of delay series, units |
30 |
SINV-Sh Delay Intervals
| Conventional Name of device |
Nominal Delay Time (tН), ms |
Interval, ms |
| SINV-SH-K-0 |
0 |
- |
| SINV-SH-K-25 |
25 |
25 |
| SINV-SH-K-50 |
50 |
25 |
| SINV-SH-K-75 |
75 |
25 |
| SINV-SH-K-100 |
100 |
25 |
| SINV-SH-K-125 |
125 |
25 |
| SINV-SH-K-150 |
150 |
25 |
| SINV-SH-K-175 |
175 |
25 |
| SINV-SH-K-200 |
200 |
25 |
| SINV-SH-K-225 |
225 |
25 |
| SINV-SH-K-250 |
250 |
25 |
| SINV-SH-K-300 |
300 |
50 |
| SINV-SH-K-350 |
350 |
50 |
| SINV-SH-K-400 |
400 |
50 |
| SINV-SH-K-450 |
450 |
50 |
| SINV-SH-K-500 |
500 |
50 |
| SINV-SH-S-25 |
25 |
- |
| SINV-SH-S-100 |
100 |
75 |
| SINV-SH-S-200 |
200 |
100 |
| SINV-SH-S-300 |
300 |
100 |
| SINV-SH-S-400 |
400 |
100 |
| SINV-SH-S-500 |
500 |
100 |
| SINV-SH-S-600 |
600 |
100 |
| SINV-SH-S-700 |
700 |
100 |
| SINV-SH-S-800 |
800 |
100 |
| SINV-SH-S-900 |
900 |
100 |
| SINV-SH-S-1000 |
1000 |
100 |
| SINV-SH-S-1250 |
1250 |
250 |
| SINV-SH-S-1500 |
1500 |
250 |
| SINV-SH-S-1750 |
1750 |
250 |
| SINV-SH-S-2000 |
2000 |
250 |
| SINV-SH-S-2250 |
2250 |
250 |
| SINV-SH-S-2500 |
2500 |
250 |
| SINV-SH-D-25 |
25 |
- |
| SINV-SH-D-500 |
500 |
475 |
| SINV-SH-D-1000 |
1000 |
500 |
| SINV-SH-D-1500 |
1500 |
500 |
| SINV-SH-D-2000 |
2000 |
500 |
| SINV-SH-D-2500 |
2500 |
500 |
| SINV-SH-D-3000 |
3000 |
500 |
| SINV-SH-D-3500 |
3500 |
500 |
| SINV-SH-D-4000 |
4000 |
500 |
| SINV-SH-D-4500 |
4500 |
500 |
| SINV-SH-D-5000 |
5000 |
500 |
| SINV-SH-D-6000 |
6000 |
1000 |
| SINV-SH-D-7000 |
7000 |
1000 |
| SINV-SH-D-8000 |
8000 |
1000 |
| SINV-SH-D-9000 |
9000 |
1000 |
| SINV-SH-D-10000 |
10000 |
1000 |
K, S, D are indexes indicating intervals between nominal response time: 25 and 50 ms for the devices with K index; 100 and 250 ms for the devices with S index; 500 and 1000 ms for the devices with D index. Nominal delay period is calculated for 4.0 m shock wave tube. Detailed technical data
|
|